inteliLIGHT® FPE-220 LonWorks® PLC compatible – electronic ballast controller
Designed for carrying out the remote management of a luminary in street lighting installations InteliLIGHT® FPE-220/220D is compatible with lamps using using electronic ballast up to 500W, with 0-10V (220) or DALI (220D) control interface.
technical details
Lamp Type | LED, CF, HID |
Maximum lamp power | 500W |
ON/ OFF function | yes |
Dimming | yes |
Dimming range | 0% – 100% |
Dimming steps | stepless |
Control interface | 0-10V / DALI |
Network interface | PowerLine CENELEC-C band |
Communication protocol | LONWORKS/ANSI709.1 |
Retransmission mechanism | yes |
Power supply | 230VAC / 50Hz – 60Hz |
Overvoltage protection | 5 minutes @ 400VAC |
Power consumption | Max. 2W |
IP rating | IP67 |
Operating temperature | -25°C to +65°C |
Dimensions (length x width x height) | 106 x 75 x 51 mm |
Certifications | CE, EN 50065-1 (2005), EN 50065-2-1 (2003),EN 61547 (2010), EN 55015 (2007), EN 61000-3-2 (2006), 60068-2-1 (2007),60068-2-2 (2007), ANSI/IEC 60529, LonMark OLC |
measured parameters
Lamp power | yes |
Line voltage | yes |
Current | yes |
Active power | yes |
Reactive power | yes |
Apparent power | yes |
Power factor | yes |
Energy consumption (active/ reactive) | yes |
Running hours | yes |
alarms monitored
Over/ under voltage detection | yes |
Over/ under current detection | yes |
Lamp or ballast fault detection | yes |
Device failure | yes |
configurable parameters
Auto on enabled/disabled/ auto on time | yes |
Auto off enabled/disabled/auto off time | yes |
Start state: ON/OFF | yes |
ON/OFF power threshold | yes |
Overvoltage threshold | yes |
Output transfer function | 0-10 V / DALI |
Strike retry count | yes |
Fade time | yes |
Lamp warming time | yes |
Lamp cooldown time | yes |
Operation mode |
|
Optional sensors available | Pole door open, pole impact detection, pole ground missing |