inteliLIGHT® FRE-220 LoRaWAN compatible luminaire controller

  • Enables individual remote management of streetlight lamps with electronic driver up to 400W (ON/ OFF/ Dimming).
  • Specially designed and optimized for LoRaWAN™ (long range RF wide area networks).
  • Autonomous operation based on predefined schedules, light level sensor and adaptive lighting.
  • Adaptive lighting capabilities based on digital input for motion sensing.
  • Bandwidth efficient with minimal communication requirements.
  • Dedicated high-security memory for encryption keys storage.
  • Wide range of electrical parameters monitoring: V, W, A, VAR, Wh, VARh, PF and frequency.
  • Advanced data synchronization and notification mechanism.
  • Battery operated RTC, protected against unforeseen communication failure.
  • External infrared interface for security keys transfer and local configuration.
  • Integrated light level sensor.
  • Over The Air (OTA) firmware update.

technical details

Lamp Type LED, CF, HID with electronic driver
Maximum lamp power 400W
Functions / Operation mode ON/ OFF /  Dimming
Dimming range 30%-100%
Dimming steps stepless
Control interface 0-10V/ 1-10V, DALI
External interface infrared
Network interface LoRaWANTM (low power, long range radio frequency)
RF spectrum 868MHz   / 915MHz  / 923MHz
Firmware update IR (infrared) / OTA (over the air)
Communication protocol LoRaWANM: Class C or Class A
Security Dedicated high-security memory for encryption keys storage
Power supply 85 – 260VAC / 50Hz-60Hz
Surge protection 10kA
Internal scheduling memory 16 events / day
Power consumption 0.5W
Precision Real Time Clock (RTC) Battery operated
Real-time lamp operation LoRaWANTM Class C networks only
IP rating IP66
Operating temperature range -25°C to +65°C
Dimensions  (length  x  width  x  height) 169,3 x 76.8 x 108.2 mm
Compliant standards CE, RoHS, EN 61000-3-2(2014), EN 61547(2009), EN 60068-2-1(2007), EN 60068-2-2(2007), Prequalified according to ETSI EN 300 220
Certifications CE /  FCC ( in progress)

measured parameters

  • Lamp power
  • Line voltage
  • Current
  • Active power
  • Reactive power
  • Apparent power
  • Power factor
  • Energy consumption (active/ reactive)
  • Lamp / controller – running hours counter
  • Lamp On / Off cycles counter

configurable parameters

  • Astronomical calendar scheduler
  • Predefined scheduler
  • Start state (Photocell / Schedule / Manual)
  • ON/OFF power threshold
  • Over/ under voltage threshold
  • Over/ under current threshold
  • Strike retry count
  • Fade time
  • Lamp warming time
  • Lamp cooldown time
  • Light level threshold
  • Data transmission setup
  • Alert priority setup

alarms monitored

  • Over/ under voltage detection
  • Over/ under current detection
  • Lamp or ballast fault detection
  • Device failure
FRE-220 LoRaWAN Compatible Luminaire Controller - Data Sheet (en)